Overview | |
Presentation | Highly efficient, modular, high-density 200kW (400/480V) 3-phase UPS that is scalable up to 500kW. It delivers top performance for medium, large, and edge data centers, as well as critical infrastructure in commercial and industrial applications. Includes 5×8 start-up service. |
Lead time | Special Order – Call for Quoted Lead Times |
General | |
Number of power module | 4 |
Number of power module free slots | 6 |
redundant | Yes |
Physical | |
colour | White |
depth | 92.5 cm |
height | 197 cm |
net weight | 495 kg |
width | 85 cm |
Input | |
network frequency | 40…70 Hz |
inputvolt_other | 400/480 V |
max short time withstand current | 65 kA |
input harmonic distortion | Less than 5 % for full load |
input voltage | 380 V 3 phases |
400 V 3 phases | |
415 V 3 phases | |
440 V 3 phases | |
480 V 3 phases | |
load power factor | 0.5 leading to 0.5 lagging without derating |
Output | |
rated power in W | 200000 W |
Maximum configurable power in W | 200000 W |
outputvolt_other | 400 V |
480 V | |
crest factor | 2.5 |
UPS type | Double conversion online |
output harmonic distortion | < 1% linear load and < 5% non-linear load |
output overload operation | 10 minutes at 125% and 60 seconds at 150% |
output voltage | 380 V 3 phases |
400 V 3 phases | |
415 V 3 phases | |
440 V 3 phases | |
480 V 3 phases | |
Maximum configurable power in VA | 200000 VA |
Environmental | |
ambient air temperature for operation | 0…40 °C |
relative humidity | 0…95 % non-condensing |
operating altitude | 0…3000 m |
ambient air temperature for storage | -25…55 °C |
Storage Relative Humidity | Non-condensing 10…80 % |
IP degree of protection | IP20 |
Batteries & Runtime | |
battery type | Li-Ion (Lithium-Ion) |
VRLA | |
Ni-Cd (Nickel-Cadmium) | |
discharge battery voltage | 384 V |
Communications & Management | |
control panel | Touch screen LCD user interface |
alarm | Audible and visible alarms prioritized by severity |
Presentation | High-efficiency 3-phase UPS that features advanced product features, competitive specifications, and robust electrical design, making business continuity easy in the data center or electrical room. This is an exceptionally easy to install, operate, maintain, and service 10 kVA UPS, ideal for small and medium businesses. Includes dust filter and conformance-coated boards for harsh environments. This UPS is for internal batteries, but is supplied without batteries, so you can easily customize the battery runtime. For battery runtime details, see the runtime charts published under the Documents tab. | |
---|---|---|
Lead time | Usually Ships within 6 Weeks |
provided equipment | Dust filter Installation guide | |
---|---|---|
UPS size | WS |
colour | White (RAL 9003) | |
---|---|---|
depth | 90.7 cm | |
height | 140 cm | |
net weight | 130 kg | |
USB compatible | Yes | |
width | 38 cm |
Input | |
network frequency | 45…65 Hz |
input voltage limits | 304…477 V |
inputvolt_other | 380 V |
415 V | |
maximum input current | 18 A |
input harmonic distortion | Less than 4 % for full load |
input voltage | 400 V 3 phases |
cos phi | 0.99 |
Output | |
rated power in W | 10000 W |
Maximum configurable power in W | 10000 W |
harmonic distortion | Less than 3 % |
output frequency | 50 Hz sync to mains |
60 Hz sync to mains | |
outputvolt_other | 220 V |
240 V | |
crest factor | 3:01 |
UPS type | Double conversion online |
output voltage tolerance | +/- 1.5 % |
output harmonic distortion | < 5.5% at 100% non-linear load |
output overload operation | 10 minutes at 125% and 60 seconds at 150% |
curve equation | Efficiency |
curve fixed loss | 0.0109 |
curve load maximum | 100 % |
curve load minimum | 2 % |
curve proportional loss | 0.0088 |
curve square loss | 0.0399 |
curve X-axis maximum | 100 % |
curve test cond ID | Curve fit to measured efficiency data. All measurements taken in normal operating mode, at typical environmental conditions, with 400V 50Hz input and 400V 50Hz balanced resistive load (PF = 1.0) output. |
curve X-axis minimum | 0 % |
curve X-axis title | Load |
curve X-axis units | Percentage |
curve Y-axis maximum | 100 % |
curve Y-axis minimum | 50 % |
curve Y-axis title | Efficiency |
curve Y-axis units | Percentage |
graph display | 1 |
output voltage | 230 V |
Maximum configurable power in VA | 10000 VA |
rated power in VA | 10000 VA |
Environmental | |
ambient air temperature for operation | 0…40 °C |
relative humidity | 0…95 % non-condensing |
operating altitude | 0…3281 ft |
ambient air temperature for storage | -25…55 °C |
Storage Relative Humidity | 0…95 % Non-condensing |
storage altitude | 0.00…15240.00 m |
acoustic level | 60 dBA |
heat dissipation | 516 Btu/h |
show note OP temperature | No |
IP degree of protection | IP20 |
Batteries & Runtime | |
battery type | VRLA |
number of battery filled slots | 0 |
number of battery free slots | 3 |
liquid value | 0 |
battery voltage | 240 V |
discharge battery voltage | +/- 198 V DC |
maximum short-circuit current | 10 kA |
battery curve | B |
show note OP temperature | No |
IP degree of protection | IP20 |